Search: -28

Results 6621 - 6630 of 7655

Results

eTraining Go back to Diabetes eTraining Page

Pumps
Diabetes Lab eTraining Slide 11

An insulin pump delivers one type of insulin and looks like a pager that can be attached to a belt, carried in a pocket, or held with a strap around the arm or thigh.

The pump connects to narrow plastic tubing that ends with a short plastic catheter inserted just under the skin in the abdomen, buttocks, or thigh.

Users set the pump to give a steady trickle or 鈥渂asal鈥 amount of insulin continuously throughout the day and 鈥渂olus鈥 doses at meals and at times when blood glucose is too high based on the user鈥檚 programming.

eTraining Go back to Diabetes eTraining Page

Bolus Insulin
Diabetes Lab eTraining Slide 8

  • AKA 鈥渞apid-acting鈥 or 鈥渟hort acting鈥 and is generally what is administered at school
  • Acts within 10-15 minutes
  • Given for one of two reasons:
    • When food is eaten
    • Glucose level is too high and needs correcting
  • Amount of insulin needed is based on the insulin to carbohydrate ratio
  • When insulin has been given prior to a meal or snack, food should be eaten soon (beginning within 15 minutes)

 

eTraining Go back to Diabetes eTraining Page

Glucose Testing Video
Diabetes Lab eTraining Slide 5

 

 

arrow_100.jpg

 

Go to next page

 

 

 

 

 

eTraining Go back to Diabetes eTraining Page

Meters
Diabetes Lab eTraining Slide 3

  • Meters do not only display numbers.  
  • Some display 鈥淟o鈥 or 鈥淗i鈥 for out of range readings. 
  • Some of them also display specific 鈥渆rror codes鈥 that may indicate problems like an insufficient blood sample or that the temperature is out of range.You will need the meter manual to respond to these error codes.
  • You can get information about a specific meter and test strips from several different sources.
  1. A copy of the manufacturer鈥檚 manual for the meter should be provided by
eTraining Go back to Diabetes eTraining Page

Lancets
Diabetes Lab eTraining Slide 2

There are many types of lancets and lancet devices.

Many students will use a lancing device. Some lancing devices have several depth settings to allow for the difference between sensitive fingers and callused fingers.  Some come with two caps for the end that touches the finger to adjust the depth of puncture. In addition, the pressure of the finger on the cap determines how deep the puncture will go. It should be deep enough to provide an adequate amount of blood, but not be so deep as to cause bruising or pain.